SEAGATE TECHNOLOGY, INC.
PEREGRINE 4586NP
Device Type | Internal Tape Drive |
Interface | SCSI-2 |
Format | DDS-2, DDS-DC |
Sustained Transfer Rate | 400 KBPS (compressed 800 KBPS) |
Size | 5.25 in. half height |
View | Top |

USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Termination disabled | JP2 | Open |
Termination enabled | JP2 | Closed | |
| » | All mode enabled | SW1/4 | On |
MRS mode enabled | SW1/4 | Off | |
| » | Parity check disabled | SW1/5 | Off |
| Parity check enabled | SW1/5 | On | |
| » | DDS-DC pass through mode enabled | SW1/6 | Off |
| DDS pass through mode enabled | SW1/6 | On | |
| » | Factory configured - do not alter | SW1/7 | Reserved |
| » | Self test disabled | SW1/8 | Off |
| Self test enabled | SW1/8 | On | |
| » | Drive mounted horizontaly | SW2/1 | Off |
| Drive mounted verticaly | SW2/1 | On | |
| » | Automatic insertion of first cartridge enabled | SW2/2 | On |
Automatic insertion of first cartridge disabled | SW2/2 | Off | |
| » | Factory configured - do not alter | SW2/3 | Reserved |
| » | Factory configured - do not alter | SW2/4 | Reserved |
| » | Continuous cycle disabled | SW3/3 | Off |
| Continuous cycle enabled | SW3/3 | On | |
| » | Display intensity light | SW3/4 | On |
| Display intensity normal | SW3/4 | Off | |
| » | Self-test sequence disabled | SW3/5 | Off |
| Self-test sequence enabled | SW3/5 | On | |
| » | Factory configured - do not alter | SW3/6 | Reserved |
| » | Factory configured - do not alter | SW3/7 | Reserved |
EXTERNAL SCSI ID SELECTION | ||||
SCSI ID | JP1/1 | JP1/2 | JP1/3 | |
| » | 0 | Off | Off | Off |
1 | Off | Off | On | |
2 | Off | On | Off | |
3 | Off | On | On | |
4 | On | Off | Off | |
5 | On | Off | On | |
6 | On | On | Off | |
7 | On | On | On | |
Note: If SCSI ID is set using SW1/1 - SW1/3, then the external SCSI ID (JP1) must be set to 0. | ||||
SCSI ID SELECTION | ||||
SCSI ID | SW1/1 | SW1/2 | SW1/3 | |
| » | 0 | Off | Off | Off |
1 | Off | Off | On | |
2 | Off | On | Off | |
3 | Off | On | On | |
4 | On | Off | Off | |
5 | On | Off | On | |
6 | On | On | Off | |
7 | On | On | On | |
Note: If SCSI ID is set using SW1/1 - SW1/3, then the external SCSI ID (JP1) must be set to 0. | ||||
LANGUAGE SELECTION | |||
Language | SW3/1 | SW3/2 | |
| » | English | On | Off |
French | Off | On | |
German | Off | Off | |
Spanish | On | On | |
MANUFACTURERS RECOMMENDED MEDIA | ||
Tape | Capacity Without Compression | Capacity With Compression |
90 meter DDS-2 DAT cartridge | 24 GB | 48 GB |
120 meter DDS-2 DAT cartridge | 48 GB | 96 GB |