ADVANCED INTERLINK CORPORATION
ANET-16/4
NIC Type | ARCnet |
Transfer Rate | 2.5Mbps |
Data Bus | 16-bit ISA |
Topology | Star |
Wiring Type | RG-62A/U 93ohm coaxial |
Boot ROM | Available |

NODE ADDRESS | ||||||||
Node | SW1/1 | SW1/2 | SW1/3 | SW1/4 | SW1/5 | SW1/6 | SW1/7 | SW1/8 |
0 | - | - | - | - | - | - | - | - |
1 | Off | On | On | On | On | On | On | On |
2 | On | Off | On | On | On | On | On | On |
3 | Off | Off | On | On | On | On | On | On |
4 | On | On | Off | On | On | On | On | On |
251 | Off | Off | On | Off | Off | Off | Off | Off |
252 | On | On | Off | Off | Off | Off | Off | Off |
253 | Off | On | Off | Off | Off | Off | Off | Off |
254 | On | Off | Off | Off | Off | Off | Off | Off |
255 | Off | Off | Off | Off | Off | Off | Off | Off |
Note: Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1) | ||||||||
RESPONSE/RECONFIGURATION TIMEOUTS | |||
Response Time | Reconfiguration Time | J1A | J1B |
74.7 m | 840ms | Open | Open |
283.4 m | 1680ms | Open | Closed |
561.8 m | 1680ms | Closed | Open |
1118.6 m | 1680ms | Closed | Closed |
Note:All NICs on the network must have this option set the same. | |||
BOOT ROM | ||
Setting | JP1C | |
» | Disabled | Open |
| Enabled | Closed |
BASE MEMORY ADDRESS | ||||||
Address | JP2A | JP2B | JP2C | JP2D | JP2E | |
| C0000h | Closed | Closed | Closed | Closed | Closed |
| C4000h | Closed | Closed | Open | Closed | Closed |
| CC000h | Closed | Open | Closed | Closed | Closed |
» | D0000h | Closed | Open | Open | Closed | Closed |
| D4000h | Open | Closed | Closed | Closed | Closed |
| D8000h | Open | Closed | Open | Closed | Closed |
| DC000h | Open | Open | Closed | Closed | Closed |
| E0000h | Open | Open | Open | Closed | Closed |
I/O BASE ADDRESS | ||||
Address | JP3A | JP3B | JP3C | |
| 260h | Closed | Closed | Closed |
| 290h | Closed | Closed | Open |
» | 2E0h | Closed | Open | Closed |
| 2F0h | Closed | Open | Open |
| 300h | Open | Closed | Closed |
| 350h | Open | Closed | Open |
| 380h | Open | Open | Closed |
| 3E0h | Open | Open | Open |
INTERRUPT REQUEST | |||||||||
IRQ | JP4A | JP4B | JP4C | JP4D | JP4E | JP4F | JP4G | JP4H | JP4I |
2 | Closed | Open | Open | Open | Open | Open | Open | Open | Open |
3 | Open | Closed | Open | Open | Open | Open | Open | Open | Open |
4 | Open | Open | Closed | Open | Open | Open | Open | Open | Open |
5 | Open | Open | Open | Closed | Open | Open | Open | Open | Open |
7 | Open | Open | Open | Open | Closed | Open | Open | Open | Open |
10 | Open | Open | Open | Open | Open | Open | Open | Open | Closed |
11 | Open | Open | Open | Open | Open | Open | Open | Closed | Open |
12 | Open | Open | Open | Open | Open | Open | Closed | Open | Open |
15 | Open | Open | Open | Open | Open | Closed | Open | Open | Open |
DIAGNOSTIC LED(S) | ||
LED | Status | Condition |
LED1 | On | Data is being transmitted or received on CON1 |
LED1 | Off | Data is not being transmitted or received on CON1 |
LED2 | On | Data is being transmitted or received on CON2 |
LED2 | Off | Data is not being transmitted or received on CON2 |
LED3 | On | Data is being transmitted or received on CON3 |
LED3 | Off | Data is not being transmitted or received on CON3 |
LED4 | On | Data is being transmitted or received on CON4 |
LED4 | Off | Data is not being transmitted or received on CON4 |