BOCA RESEARCH, INC.
BOCAMODEM V.34 DATA/FAX (MV.34I)
Modem Type | Data (synchronous/asynchronous)/Fax |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | 8 bit ISA |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.32, V.32bis, V.34 Rockwell V.FC |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |

CONNECTIONS | |||
Purpose | Location | Purpose | Location |
Line in | CN1 | Line out | CN2 |
| SERIAL PORT ADDRESS | ||||
Setting | JP1/A | JP1/B | JP1/C | JP1/D |
COM1 (3F8h) | Closed | Open | Open | Open |
COM2 (2F8h) | Open | Closed | Open | Open |
| » COM3 (3E8h) | Open | Open | Closed | Open |
COM4 (2E8h) | Open | Open | Open | Closed |
INTERRUPT | ||||
Setting | JP1/E | JP1/F | JP1/G | JP1/H |
3 | Closed | Open | Open | Open |
4 | Open | Closed | Open | Open |
| » 5 | Open | Open | Closed | Open |
7 | Open | Open | Open | Closed |
Proprietary AT Command Set
MAXIMUM BLOCK SIZE FOR TRANSMISSION | |
Type: | Configuration |
Format: | AT [cmds] \An [cmds] |
Description: | Sets the maximum transmittable block size |
Command | Function |
\A0 | MNP block size is 64 characters |
| » \A1 | MNP block size is 128 characters |
\A2 | MNP block size is 192 characters |
\A3 | MNP block size is 256 characters |
BREAK SEND | |
Type: | Immediate |
Format: | AT [cmds] \Bn [cmds] |
Range: | 1-9 |
Default: | 3 |
Unit: | .1 second |
Description: | Sends break to modem |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] \Gn [cmds] |
Description: | Selects modem port flow control |
Command | Function |
\G0 | Flow control disabled |
\G1 | Flow control enabled |
BREAK TYPE | ||||
Type: | Configuration | |||
Format: | AT [cmds] \Kn [cmds] | |||
Description: | Configures action of break signal | |||
Command | Break from DTE while in auto reliable mode | Modem receives \B while in normal mode | Break from DTE while in direct mode | |
\K0 | Online command mode enabled, send no break to remote modem | Break sent to remote modem and buffered cleared | Break sent and modem enters command mode | |
\K1 | Break sent to remote modem and buffered cleared | Break sent to remote modem and buffered cleared | Break sent and modem enters command mode | |
\K2 | Online command mode enabled, send no break to remote modem | Send break to remote modem immediately | Break sent to remote modem | |
\K3 | Send break to remote modem immediately | Send break to remote modem immediately | Break sent and modem enters command mode | |
\K4 | Online command mode enabled, send no break to remote modem | Send break with transmitted data | Break sent to remote modem | |
| » \K5 | Send break with transmitted data | Send break with transmitted data | Break sent to remote modem | |
PROTOCOL | |
Type: | Configuration |
Format: | AT [cmds] \Nn [cmds] |
Description: | Sets connect mode |
Command | Function |
\N0 | Normal mode enabled |
\N1 | Direct mode enabled |
\N2 | Reliable mode enabled |
| » \N3 | Auto reliablel mode enabled |
\N4 | LAP-M mode enabled |
\N5 | MNP mode enabled |
COMPRESSION | |
Type: | Configuration |
Format: | AT %Cn |
Description: | Selects data compression |
Command | Function |
%C0 | Data compression disabled |
%C1 | MNP5 data compression enabled |
%C2 | V.42bis data compression enabled |
| » %C3 | MNP5 and V.42bis data compression enabled |
AUTO-RETRAIN - FALLBACK/FALLFORWARD | |
Type: | Configuration |
Format: | AT [cmds] %En [cmds] |
Description: | Controls auto-retrain mode and fallback/fall forward |
Command | Function |
%E0 | Auto-retrain disabled |
%E1 | Auto-retrain enabled |
| » %E2 | Fallback/fall forward enabled |
LINE SIGNAL LEVEL | |
Type: | Immediate |
Format: | AT [cmds] %L [cmds] |
Range: | 009-043 |
Unit | -1dBm |
Description: | Displays received line signal level |
REPORT SIGNAL QUALITY | |
Type: | Immediate |
Format: | AT [cmds] %Q [cmds] |
Range: | 0-255 |
Unit: | High order byte of calculated eye quality monitor |
Description: | Reports signal quality. If the value is greater than 8, the modem will retrain |
MODULATION SELECTION | |
Type: | Configuration |
Format: | AT [cmds] +MS=xx,y,zzz,aaa [cmds] |
Description: | Sets options for active protocol. The transfer rates specified by z and a must be valid for the protocol selected. |
Command | Function |
x=0 | V.21 |
x=1 | V.22 |
x=2 | V.22bis |
x=3 | V.23 |
x=9 | V.32 |
x=10 | V.32bis |
| » x=11 | V.34 |
x=64 | Bell 103A |
x=69 | Bell 212A |
x=74 | V.FC |
y =0 | Automode disabled |
y =1 | Auto-detect highest speed enabled |
z, a =300 | Set minimum or maximum transfer rate at 300bps, respectively |
z, a =1200 | Set minimum or maximum transfer rate at 1200bps, respectively |
z, a =2400 | Set minimum or maximum transfer rate at 2400bps, respectively |
z, a =4800 | Set minimum or maximum transfer rate at 4800bps, respectively |
z, a =7200 | Set minimum or maximum transfer rate at 7200bps, respectively |
z, a =9600 | Set minimum or maximum transfer rate at 9600bps, respectively |
z, a =12000 | Set minimum or maximum transfer rate at 12000bps, respectively |
z, a =14400 | Set minimum or maximum transfer rate at 14400bps, respectively |
z, a =16800 | Set minimum or maximum transfer rate at 16800bps, respectively |
z, a =19200 | Set minimum or maximum transfer rate at 19200bps, respectively |
z, a =21600 | Set minimum or maximum transfer rate at 21600bps, respectively |
z, a =24000 | Set minimum or maximum transfer rate at 24000bps, respectively |
z, a =26400 | Set minimum or maximum transfer rate at 26400bps, respectively |
z, a =28800 | Set minimum or maximum transfer rate at 28800bps, respectively |
SLEEP TIMER | |
Format | AT [cmds] S24=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Seconds |
Description: | Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode |
FLASH DIAL MODIFIER TIME | |
Format | AT [cmds] S29=n [cmds] |
Default: | 10 |
Range: | 0-255 |
Unit: | 1ms |
Description: | Time the modem will go on-hook upon receiving the ! dial modifier in dial string |
FLOW CONTROL CHARACTER - XOFF | |
Type: | Register |
Format: | AT [cmds] S33=n [cmds] |
Default: | 19 |
Range: | 0-255 |
Unit: | ASCII |
Description: | Sets the character used to represent XOFF |
FLOW CONTROL CHARACTER - XON | |
Type: | Register |
Format: | AT [cmds] S32=n [cmds] |
Default: | 17 |
Range: | 0-255 |
Unit: | ASCII |
Description: | Sets the character used to represent XON |
PROTOCOL/SPEED | |
Format | AT [cmds] S37=n [cmds] |
Default: | 0 |
Range: | 0-12 |
Description: | Selects switched line speed |
Command | Function |
| » S37=0 | Connect at highest common speed |
S37=1 | Connect at300bps |
S37=2 | Connect at 300bps |
S37=3 | Connect at 300bps |
S37=4 | Not used |
S37=5 | Connect at 1200bps |
S37=6 | Connect at 2400bps |
S37=7 | Connect at V.23 |
S37=8 | Connect at 4800bps |
S37=9 | Connect at 9600bps |
S37=10 | Connect at 12.0Kbps |
S37=11 | Connect at 14.4Kbps |
S37=12 | Connect at 7200bps |
FAX TRANSMIT LEVEL | |
Type: | Register |
Format: | AT [cmds] S92=n [cmds] |
Default: | 10 |
Range: | 0-15 |
Unit: | -1dBm |
Description: | Controls fax transmission level |
BIT MAPPED REGISTERS | |
Register | Default |
S14 | 138 |
S16 | 0 |
S21 | 4 |
S22 | 117 |
S23 | 54 |
S27 | 9 |
S28 | 0 |
S31 | 2 |
S39 | 3 |
S40 | 104 |
S41 | 3 |