M K - 1 0 3 4 F C TOSHIBA
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 1354| 664| |
Capacity form/unform 106/ MB Heads 4| 8| |
Seek time / track 16.0/ 5.0 ms Sector/track 40| 39| |
Controller IDE / AT Precompensation
Cache/Buffer 64 KB Landing Zone
Data transfer rate 1.600 MB/S int Bytes/Sector 512
5.900 MB/S ext
Recording method RLL 2/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 50 | -40 60
Power: sleep W Humidity % |
standby 0.5 W Altitude km |
idle 2.5 W Shock g 5 | 75
seek 4.8 W Rotation RPM 3400
read/write 3.5 W Acoustic dBA
spin-up 12.0 W ECC Bit 32,56
MTBF h 80000
Warranty Month
Lift/Lock/Park YES Certificates
TOSHIBA MK-1034FC PRODUCT DESCRIPTION
+---------------------------------------------------------+ | |XX Power | |XX 4 Pin | | | |XX I | |XX N |1-+PJ4 |XX T PJ11 || | |XX E || | |XX R |+-+ |XX F | |XX A | |XX C | |XX E | |XX | |XX | | | |XX Power +---------------------------------------------------------+ 3 Pin
TOSHIBA MK1034FC PRODUCT DESCRIPTION
Jumper Setting
==============
+--------------------------------------------------+
| +-------+ +---------+ |
| | o o o | xxxxxxxxxxxxxxxxxxxxxxxx | o o o o | |
+-+-1-2-3-+----------------------------+-4-3-2-1-+-+
| | +--- +5V | | | +--- +12 VDC
| +----- +12V | | +----- +12V Return
+------- +GND | +------- +5V Return
+--------- +5 VDC
PJ4 LED/Slave Present/Master/Slave/Drive Present/ECC/Auto Start
---------------------------------------------------------------
+-----+
1 o o 2 LED
| o o | SLV PRS
5 o o 6 MST/SLV
| o o | DRV PRS
9 o o 10 ECC
| o o | DIS Auto Start
+-----+
PJ4 LED
--------
1-2 CLOSED Connects the active signal to the HOST SLAVE/ACTIVE
signal (PJ11-39) on the interface connector.
This signal provides the capability to drive an
external LED. An external current limiting resistor
is required.
PJ4 Slave Present
------------------
3-4 CLOSED The HOST SLAVE/ACTIVE signal (PJ11-39) on the
interface to the ground for the systems that
require the slave drive to provide SLAVE PRESENT
signal from the slave drive to a 2-drive system.
This jumper PJ4-3/4 and PJ4-1/2 are mutually
exclusive. Use should not install both jumpers.
PJ4 Master/Slave
-----------------
5-6 CLOSED Drive is Master
OPEN Drive is Slave
PJ4 Slave Drive Present
------------------------
7-8 CLOSED Slave drive is present
In a 2-drive system, this jumper must be installed in the Master
drive.
PJ4 ECC
--------
9-10 CLOSED 4-Bytes ECC mode on Read and Write Long commands.
OPEN 7-Bytes ECC
PJ4 DIS Auto Start
-------------------
11-12 CLOSED The drive will be in STANDBY mode after power
on. This means the spindle motor will not rotate
and only the interface part is functioning. The
drive will spin-up when a command is executed. The
Auto Standby mode is not enabled by this jumper.
OPEN The drive will be in Idle-1 mode after power on.