S Q 3 1 0 5 S SYQUEST
Native| Translation
------+-----+-----+-----
Form 3.5"/HH Cylinders | | |
Capacity form/unform 105/ MB Heads | | |
Seek time / track 14.5/ ms Sector/track | | |
Controller SCSI1 SINGLE-ENDED Precompensation
Cache/Buffer 64 KB Landing Zone
Data transfer rate 1.950 MB/S int Bytes/Sector 512
MB/S ext
Recording method operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C |
Power: sleep W Humidity % |
standby W Altitude km |
idle W Shock g 5 | 80
seek W Rotation RPM
read/write W Acoustic dBA
spin-up W ECC Bit
MTBF h 100000
Warranty Month
Lift/Lock/Park YES Certificates
SYQUEST SQ3105S
+---------------------------------------------------------+ | +-----+ X |XX | +-+8 +-----+ TEX |XX | | | +-----+ X |XX | JP2 | | +-----+ X |XX | +-+1 |XX | +---------+ X |XX | | | TerminatorX |XX | | | X |XX | +---------+ X |XX | |XX | |XX1 | | | |XX+5V | |XXPower +---------------------------------------------------------+
TE = Terminator
SYQUEST SQ3105S JUMPER SETTING
Jumper Setting
==============
JP2 1/2/3 SCSI ID
-----------------
Pins 3 = SCSI ID2
Pins 2 = SCSI ID1
Pins 1 = SCSI ID0
+----------+-----------------------+ | SCSI ID | Jumpers | | | ID2 | ID1 | ID0 | +----------+-------+-------+-------+ | 0 | OPEN | OPEN | OPEN | +----------+-------+-------+-------+ | 1 | OPEN | OPEN | CLOSED| +----------+-------+-------+-------+ | 2 | OPEN | CLOSED| OPEN | +----------+-------+-------+-------+ | 3 | OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+ | 4 | CLOSED| OPEN | OPEN | +----------+-------+-------+-------+ | 5 | CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+ | 6 | CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+ | 7 | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+
JP2 Pin 4 => ODD Parity
JP2 Pin 5 => NEC COMPATIBLE
JP2 Pin 6 => Asynchron Transfer
JP2 Pin 7 => RESERVED
JP2 Pin 8 => RESERVED