STORAGE DIMENSIONS
SDC-801
Data bus: 8-bit, PC/XT, PC/AT
Size: Half-length, full-height card
Hard drives supported: Up to seven SCSI devices
Floppy drives supported: None

CONNECTION | |
Function | Location |
50-pin SCSI connector-internal | CN1 |
BIOS ADDRESS | ||||||||
Address | JP1/1 | JP1/2 | JP1/3 | JP1/4 | JP1/5 | JP1/6 | JP1/7 | JP1/8 |
C000h | closed | open | open | open | open | open | open | open |
C400h | open | closed | open | open | open | open | open | open |
C800h | open | open | closed | open | open | open | open | open |
CC00h | open | open | open | closed | open | open | open | open |
D000h | open | open | open | open | closed | open | open | open |
D400h | open | open | open | open | open | closed | open | open |
D800h | open | open | open | open | open | open | closed | open |
DC00h | open | open | open | open | open | open | open | closed |
INTERRUPT REQUEST | |||||
IRQ | JP2/jumper 1 | JP2/jumper 2 | JP2/jumper 3 | JP2/jumper 4 | JP2/jumper 5 |
Disabled | closed | open | open | open | open |
IRQ3 | open | closed | open | open | open |
IRQ4 | open | open | closed | open | open |
IRQ5 | open | open | open | closed | open |
IRQ7 | open | open | open | open | closed |
ZERO WAIT STATE | |||
Select | JP3/jumper 1 | JP3/jumper 2 | |
| » | Zero wait state enabled | closed | open |
Zero wait state disabled | open | closed | |