stason.org logo lotus


previous page: SUPRAFAX MODEM 24/96 modem/telephone/ISDN Settings and Configurationpage up: Modems and Telephone/ISDN cards Specs: S-Tnext page: SUPRAFAX MODEM 288I PNP modem/telephone/ISDN Settings and Configuration

SUPRAFAX MODEM 288I modem/telephone/ISDN Settings and Configuration

 Books
 TULARC


















SUPRA DIAMOND

SUPRAFAX MODEM 288I

Card Type

Fax, Modem (asynchronous)

Chip Set

Rockwell

Maximum Data Rate

28.8Kbps

Maximum Fax Rate

14.4Kbps

Data Bus

8-bit ISA

Fax Class

Class I & II

Data Modulation Protocol

Bell 103/212A

ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34

Rockwell V.FC

Fax Modulation Protocol

ITU-T V.17, V.21CH2, V.27ter, V.29

Error Correction/Compression

MNP5, MNP10, V.42, V.42bis

CONNECTIONS

Function

Label

Function

Label

Line out/in - Unidentified

CN1

Line in/out - Unidentified

CN2

SERIAL PORT ADDRESS

Setting

SEL/0

SEL/1

COM1 (3F8h)

Open

Open

í COM2 (2F8h)

Closed

Open

COM3 (3E8h)

Open

Closed

COM4 (2E8h)

Closed

Closed

INTERRUPT

Setting

IRQ/2

IRQ/3

IRQ/4

IRQ/5

2

Closed

Open

Open

Open

í 3

Open

Closed

Open

Open

4

Open

Open

Closed

Open

5

Open

Open

Open

Closed

Proprietary AT Command Set

AUTO-FALLBACK/FALL-FORWARD

Type:

Configuration

Format:

AT [cmds] %Gn [cmds]

Description:

Selects auto-fallback/fall-forward

Command

Function

%G0

Auto-fallback/fall-forward disabled

í %G1

Auto-fallback/fall-forward enabled

AUTO-RETRAIN

Type:

Configuration

Format:

AT [cmds] %En [cmds]

Description:

Controls auto-retrain mode

Command

Function

í %E0

Auto-retrain disabled

%E1

Auto-retrain enabled

BIT-MAPPED REGISTER S13

Format:

AT [cmds] S13=n [cmds]

Default:

0

Range:

0-8

Description:

Controls DTR dialing during asynchronous mode

Bit

Value

Function

2 - 0

í 000

Not used

3

í 0

1

DTR auto-dialing In asynchronous mode disabled

DTR auto-dialing In asynchronous mode enabled

BIT-MAPPED REGISTER S14

Format:

AT [cmds] S14=n [cmds]

Default:

Unidentified

Range:

0-174

Unit:

Bit-mapped

Description:

Controls echo, result codes and display, dial mode, and answer/originate mode.

Bit

Value

Function

0

í 0

Not used

1

0

í 1

Command echo disabled

Command echo enabled

2

í 0

1

Result codes enabled

Result codes disabled

3

0

í 1

Display result codes in numeric format

Display result codes in verbose format

4

í 0

Not used

5

í 0

1

Tone dial enabled

Pulse dial enabled

6

í 0

Not used

7

0

1

Answer mode enabled

Originate mode enabled

BIT-MAPPED REGISTER S21

Format

AT [cmds] S21=n [cmds]

Default:

4

Range:

0-253

Unit:

Bit-mapped

Description:

Selects jack type, CTS/DCD/DSR signals, low DTR action, and the long space disconnect function.

Bit

Value

Function

0

í 0

1

Selects RJ-11, RJ-41S, or RJ45S jack

Selects RJ-12 or RJ-13 jack

1

í 0

Not used

2

0

í 1

CTS forced high

CTS follows RTS

4, 3

í 00

01

10

11

Modem does not respond to DTR

Modem hangs-up if off-hook & auto-answer is disabled

Modem hangs up if off-hook & auto-answer not disabled

Modem switches to asynchronous command state

5

í 0

1

DCD forced high

DCD normal

6

í 0

1

DSR forced high

DSR normal

7

í 0

1

Long space disconnect function disabled

Long space disconnect function enabled

BIT-MAPPED REGISTER S22

Format

AT [cmds] S22=n [cmds]

Default:

118

Range:

0-127

Unit:

Bit-mapped

Description:

Controls speaker volume and controls, and limits results codes.

Bit

Value

Function

1, 0

00

01

í 10

11

Low level volume

Low level volume

Medium level volume

High level volume

3, 2

00

í 01

10

11

Speaker off

Speaker off on carrier

Speaker always on

Speaker on during handshake

6 - 4

000

100

101

110

í 111

Basic result codes only enabled

Basic and connection speed result codes enabled

Basic and connection speed result codes and dialtone detection enabled

All result codes except dialtone detection enabled

All result codes enabled

BIT-MAPPED REGISTER S23

Format

AT [cmds] S23=n [cmds]

Default:

55

Range:

0-189

Unit:

Bit-mapped

Description:

Grants/denies remote digital loopback, controls DTE rate and parity, and sets guard tone.

Bit

Value

Function

0

0

í 1

Remote digital loopback denied

Remote digital loopback allowed

3 - 1

000

001

010

í 011

100

101

110

111

Sets serial port speed to 0-300bps

Sets serial port speed to 600bps

Sets serial port speed to 1200bps

Sets serial port speed to 2400bps

Sets serial port speed to 4800bps

Sets serial port speed to 9600bps

Sets serial port speed to 19200bps

Sets serial port speed to 38400bps or higher

5, 4

00

01

10

í 11

Parity even

Not Used

Parity odd

No Parity

7, 6

í 00

01

10

Guard tone disabled

Guard tone 550Hz enabled

Guard tone 1800Hz enabled

BIT-MAPPED REGISTER S27

Format

AT [cmds] S27=n [cmds]

Default:

73

Range:

0-11

Unit:

Bit-mapped

Description:

Selects synchronous/asynchronous mode, line type, clock source, and ITU-T/Bell modes.

Bit

Value

Function

3, 1, 0

000

001

010

011

100

í 101

110

Asynchronous Direct mode

Asynchronous off-line command mode and synchronous connect mode

Asynchronous off-line command mode - modem auto-dials first number in directory, then synchronous connect mode.

Asynchronous off-line command mode on low DTR, synchronous connect mode on high DTR.

Not Used

Asynchronous Reliable Mode

Asynchronous Normal Mode

2

í 0

1

Switched line (PSTN/Dial-up)

Leased line

5, 4

í 00

01

10

Modem generates clock

DTE generates clock

Modem generates clock from the receive carrier signal

6

0

í 1

ITU/T mode

Bell mode

BIT-MAPPED REGISTER S28

Format

AT [cmds] S28=n [cmds]

Default:

Unidentified

Range:

0-31

Unit:

Bit-mapped

Description:

Controls V.23 split speed, transmit/receive speed, half duplex; and pulse dialing.

Bit

Value

Function

0

í 0

1

V.23 split speed operation disabled

V.23 split speed operation enabled

1

0

1

75bps transmit, 1200bps receive enabled

1200bps transmit, 75bps receive enabled

2

0

1

1200bps transmit, 1200bps receive disabled

1200bps transmit, 1200bps receive enabled

4, 3

í 00

01

10

11

39ms make/61ms break at 10pps

33ms make/67ms break at 10pps

39ms make/61ms break at 20pps

33ms make/67ms break at 20pps

BIT-MAPPED REGISTER S31

Format:

AT [cmds] S31=n [cmds]

Default:

2

Range:

0-10

Description:

Select automode and extended result code format.

Bit

Value

Function

0

í 0

Not used

1

0

í 1

Auto-mode disabled

Auto-mode enabled

3, 2

í 00

01

10

Enables CONNECT result codes to report DTE speed

Full reporting of CONNECT result codes

Enables CONNECT result codes to report DCE speed

BIT-MAPPED REGISTER S40

Format

AT [cmds] S40=n [cmds]

Default:

Unidentified

Range:

0-239

Unit:

Bit-mapped

Description:

Controls power level and break handling; selects MNP extended services, link negotiation, and block size.

Bit

Value

Function

0

0

1

V.42 LAPM to MNP 10 connection disabled

V.42 LAPM to MNP 10 connection enabled

1

0

í 1

Power level adjustment disabled

Power level adjustment enabled

2

í 0

1

Link will be negotiated at highest possible speed

Link will be negotiated at 1200bps

5, 4, 3

000

001

010

011

100

í 101

\K0

\K1

\K2

\K3

\K4

\K5

7, 6

00

01

í 10

11

MNP block size is 64 characters

MNP block size is 128 characters

MNP block size is 192 characters

MNP block size is 256 characters

BIT-MAPPED REGISTER S41

Format

AT [cmds] S41=n [cmds]

Default:

Unidentified

Range:

0-31

Unit:

Bit-mapped

Description:

Selects compression, auto-retrain, flow control, and MNP mode.

Bit

Value

Function

1 - 0

00

01

10

11

Data compression disabled

MNP5 enabled

V.42bis enabled

MNP5 and V.42bis enabled

2

í 0

1

Auto-retrain disabled

Auto-retrain enabled

3

í 0

1

Flow control disabled

Flow control enabled

4

í 0

1

Stream mode for MNP

Block mode for MNP

BIT-MAPPED REGISTER S192

Format:

AT [cmds] S192=n [cmds]

Default:

2

Range:

0-243

Description:

Controls silent Answer Snoop Mode, adaptive answer mode, V.34 rate limiting, rate renegotiating display, demo mode, and silent answer reason code

Bit

Value

Function

0

í 0

1

Standard - Full CNG. A "Snoop" occurs for 3 seconds after each ring, and for 12 seconds after the last ring.

Fast - CNG Tone Only. A "Snoop" occurs for 3 seconds after each ring, and for 5 seconds after the last ring.

1

0

 

 

í 1

Attempt data carrier first (FAX fallback if failed data).

In this mode, adaptive answer accept data carriers primarily and switches to FAX mode if DATA was not successful. No CNG tone required, any and all failed DATA connections are handled as valid FAX call attempts.

Attempt data carrier first (FAX if CNG tone).

In this mode, adaptive answer accept data carriers primarily wait until data carrier answer tone for 4 seconds to allow a possible CNG tone detect to occur; but switches to FAX mode when a CNG tone is detected.

3, 2

í 00

Not used

4

í 0

1

V34 rate limiting disabled

V34 rate limiting enabled; The modem will connect using the rate from +MS, after a connection is made all data rates more than one step below the connection rate will be disabled.

5

í 0

1

Rate Renegotiating Display disabled

Rate Renegotiating Display enabled

6

í 0

1

Demo Mode disabled

Demo Mode enabled; modem displays V34 288 LP DC as if it is connected. Issue ATZ to return normal operation.

7

í 0

1

Silent answer reason code disabled

Silent answer reason code enabled; "CNG -- SA": Silent Answer or Silent Answer Plus code detects CNG. "CNG -- Adaptive Answer": Adaptive Answer code detects CNG. "DATA Time-out": Data mode timed out during an Adaptive Answer.

BIT-MAPPED REGISTER S201

Format:

AT [cmds] S201=n [cmds]

Default:

Unidentified

Range:

0-63

Description:

Controls power level, and compromise equalizer.

Bit

Value

Function

4 - 0

00000

00001

00010

...

01010

01011

...to...

11111

Initial power level -26dBm

Initial power level -30dBm

Initial power level -10dBm

...

Initial power level -10dBm

Initial power level -11dBm

...to...

Initial power level -31dBm

5

0

1

Equalizer disabled

Equalizer enabled

BIT-MAPPED REGISTER S210

Format:

AT [cmds] S210=n [cmds]

Default:

Unidentified

Range:

0-13

Description:

Controls Baud rate and V.34 asymmetric carrier rate.

Bit

Value

Function

2 - 0

000

001

010

011

100

í 101

Baud rate Data rates

2400 2400 - 21800bps

2400 4800 - 24000bps

2400,2800 4800 - 24000bps

2400,2800,3000 4800 - 26400bps

2400,2800,3000,3200 4800 - 28800bps

2400,2800,3000,3200,3429 4800 - 28800bps

3

0

1

V.34 transmit and receive carriers use the same rate

V.34 transmit and receive Carriers may use different rates

BLACKLISTED NUMBERS

Type:

Immediate

Format:

AT [cmds] *B [cmds]

Description:

Displays a numbered chart of BLACKLISTED numbers, except permanently forbidden numbers based on country setting. "OK" is returned if no numbers are blacklisted.

BREAK SEND

Type:

Configuration

Format:

AT [cmds] \Bn [cmds]

Default:

Unidentified

Range:

1-9

Unit:

.1 second

Description:

Sends break to modem in non-error correction state

BREAK TYPE

Type:

Configuration

Format:

AT [cmds] \Kn [cmds]

Description:

Configures action of break signal

Command

Break from DTE

Modem receives \B

Break received from remote modem

\K0

Online command mode enabled, send no break to remote modem

Break sent to remote modem and buffers cleared

Buffers cleared, break sent to DTE

\K1

Break sent to remote modem and buffers cleared

Break sent to remote modem and buffers cleared

Buffers cleared, break sent to DTE

\K2

Online command mode enabled, send no break to remote modem

Send break to remote modem immediately

Break sent immediately to DTE

\K3

Send break to remote modem immediately

Send break to remote modem immediately

Break sent immediately to DTE

\K4

Online command mode enabled, send no break to remote modem

Send break with transmitted data

Break sent with received data to the DTE

í \K5

Send break with transmitted data

Send break with transmitted data

Break sent with received data to the DTE

CALLER ID

Type:

Configuration

Format:

AT [cmds] #CID=n [cmds]

Description:

Controls the Caller ID function

Command

Function

#CID?

Displays current Caller ID mode

#CID=?

Returns Caller ID modes supported

#CID=0

Caller ID disabled

#CID=1

Caller ID displays formatted data

#CID=2

Caller ID displays raw hexadecimal data

COMMUNICATIONS MODE

Type:

Configuration

Format:

AT [cmds] &Mn [cmds]

Description:

Selects communications mode

Note: Same function as &Q(0-3) settings.

Command

Mode

í &M0

Asynchronous Direct mode

&M1

Asynchronous off-line command mode and synchronous connect mode.

&M2

Asynchronous off-line command mode - modem auto-dials first number in directory, then synchronous connect mode.

&M3

Asynchronous off-line command mode on low DTR, synchronous connect mode on high DTR.

COMMUNICATIONS MODE

Type:

Configuration

Format:

AT [cmds] &Qn [cmds]

Description:

Selects communications mode options

Command

Mode

&Q0

Asynchronous Direct mode

&Q1

Asynchronous off-line command mode and synchronous connect mode.

&Q2

Asynchronous off-line command mode - modem auto-dials first number in directory, then synchronous connect mode.

&Q3

Asynchronous off-line command mode on low DTR, synchronous connect mode on high DTR.

&Q4

Not Used

í &Q5

Asynchronous Reliable Mode

&Q6

Asynchronous Normal Mode

Note: Be VERY careful when issuing these commands! Once you enter &Q(1-3) and save it to memory,

there are only two known ways to return to Asynchronous Mode:

1. Issue AT &Q(0,5-9) &W from a Synchronous Terminal to restore the modem to Asynchronous Mode.

2. Connect modem to an Asynchronous Terminal with the DTR signal (line 20) disabled (a "break-out" box works very nicely for this) and issue the configuration you want or AT &Q(0,5-9) &W to return the modem to Asynchronous Mode.

COMMUNICATION PROTOCOLS

Type:

Configuration

Format:

AT [cmds] Bn [cmds]

Description:

Selects the communication protocol for data calls

Note: The B command allows the simultaneous selection of more than one suffix, enabling multiple protocols.

Command

Function

B0

V.21 (1200bps) and V.22 (1200 bps)

B1

Bell 103 (300 bps) and Bell 212A (1200 bps)

COMPRESSION

Type:

Configuration

Format:

AT [cmds] %Cn [cmds]

Description:

Selects data compression

Command

Function

%C0

Data compression disabled

%C1

MNP5 enabled

%C2

V.42bis enabled

%C3

MNP5 and V.42bis enabled

CONNECT MODE

Type:

Configuration

Format:

AT [cmds] \Nn [cmds]

Description:

Controls the type of connection the modem will operate in

Command

Function

\N0

Normal mode enabled

\N1

Direct mode enabled

\N2

Reliable mode enabled

í \N3

Auto-reliable mode enabled

\N4

V.42 reliable mode enabled

\N5

MNP reliable mode enabled

COUNTRY CODE

Type:

Configuration

Format:

AT [cmds] *NCn [cmds]

Description:

Sets the country code

Command

Function

Command

Function

*NC?

Displays country codes and configurations currently supported

*NC013

Spain

*NC000

United States

*NC014

Sweden

*NC001

Austria

*NC015

Switzerland

*NC002

Belgium

*NC016

United Kingdom

*NC003

Denmark

*NC017

Greece

*NC004

Finland

*NC020

Canada

*NC005

France

*NC021

Mexico

*NC006

Germany

*NC022

United States

*NC007

Ireland

*NC040

Australia

*NC008

Italy

*NC043

Japan

*NC010

Netherlands

*NC047

Singapore

*NC011

Norway

*NC048

New Zealand

*NC012

Portugal

*NC060

South Africa

DATA TERMINAL READY (DTR)

Type:

Configuration

Format:

AT [cmds] &Dn [cmds]

Description:

Selects modem response to DTR

Note: The action each variant of &D causes depends on the setting of &Q

&Q Setting

&D0

&D1

&D2

&D3

&Q0, &Q5, &Q6

Command 0

Command 3

Command 1

Command 4

&Q1, &Q4

Command 2

Command 3

Command 1

Command 4

&Q2, &Q3

Command 1

Command 1

Command 1

Command 1

Command

Function

Command 0

Modem does not respond to DTR

Command 1

Modem hangs-up if off-hook & auto-answer is disabled

Command 2

Modem hangs up if off-hook & auto-answer not disabled

Command 3

Modem switches to asynchronous command state

Command 4

Modem performs soft reset

DELAYED NUMBERS

Type:

Immediate

Format:

AT [cmds] *D [cmds]

Description:

Displays a numbered chart of DELAYED numbers and the length of delay in the format HH:MM:SS. "OK" is returned if no numbers are delayed.

DIAL

Type:

Immediate

Format:

AT [cmds] D<#> [cmds]

Description:

Dials telephone number according to any modifiers included in the string

Note: Any combination of modifiers can be used to produce the desired dial functions in sequence.

Command

Function

- ( ) i

These symbols and spaces are ignored

L

Dial the last dialing string

J

Perform MNP10 link negotiation at 1200bps (one-shot)

K

Enable power level adjustment during MNP10 link negotiation (one-shot)

P

Pulse dial the following digits

R

Accepted, but no action occurs

Sn

Use dialing string stored in register n. n=0-3

T

Tone dial the following digits

W

Wait for second dialtone, Within the time set in S6 and/or S7

*

DTMF code for "star"

#

DTMF code for "gate"

&

Wait for "bong" Credit Card billing tone

@

Wait for quiet answer, A 5 second silence.

,

Pause before finishing dialing string, time set in S8

!

Hook flash, go on-hook for 700ms, maybe changed by S29.

^

Turn on 1300Hz call originating pulse

;

Return to command state

DIALING CODES

Type:

Configuration

Format:

AT [cmds] *Zn [cmds]

Description:

Sets pulse dialing. Used for countries that supports 2 pulse dialing methods.

Command

Function

í *Z0

Dial code 0

*Z1

Dial code 1

DISTICTIVE RING

Type:

Configuration

Format:

AT [cmds] -SDR=n [cmds]

Default:

0

Range:

0-7

Description:

Selects distinctive ring and result code

Note: -SDR? = Reports current distinctive ring used

Bit

Value

Function

0

í 0

1

Single rings and report as RING 1 disabled

Single rings and report as RING 1 enabled

1

í 0

1

Double rings and report as RING 2 disabled

Double rings and report as RING 2 enabled

2

í 0

1

Triple rings and report as RING 3 disabled

Triple rings and report as RING 3 enabled

DISPLAYS CURRENT SETTINGS

Type:

Immediate

Format:

AT [cmds] \S [cmds]

Description:

Displays Active Configuration

DISPLAYS MANUFACTURER

Type:

Immediate

Format:

AT [cmds] +GMI [cmds]

Description:

Displays manufacturer ID

DISPLAYS MODEL

Type:

Immediate

Format:

AT [cmds] +GMM [cmds]

Description:

Displays model ID

DISPLAYS ROM CODE

Type:

Immediate

Format:

AT [cmds] +GMR [cmds]

Description:

Displays ROM Code ID

EQM AUTOMATIC RATE ADAPTION BIAS

Type:

Register

Format

AT [cmds] S191=n [cmds]

Default:

129

Range:

0-255

Unit:

Unidentified

Description:

Controls the bias for V.32/32bis,V.FC, and V.34 operation. Linked to AT%Q, but doesn’t affect it.

EQM QUALITY TIMER

Type:

Register

Format

AT [cmds] S190=n [cmds]

Default:

60

Range:

10-255

Unit:

1 second

Description:

Sets the minimum time period the EQM (%Q) level must be "GOOD" before attempting to fall-forward to a higher rate. Affects AT%E2%G1 setting

FACTORY DEFAULT PROFILE

Type:

Configuration

Format:

AT [cmds] &F [cmds]

Description:

Sets values in active profile to values found in the default profile

Command

Function

&F0

No flow control, No error correction, No data compression

&F1

MAC hardware flow control, correction & compression active

&F2

Hardware flow control, correction & compression active

FLASH DIAL MODIFIER TIME

Type:

Register

Format

AT [cmds] S29=n [cmds]

Default:

7

Range:

0-255

Unit:

.1 second

Description:

Time the modem will go on-hook upon receiving the ! dial modifier in dial string. S29=0 will disable flash hook function.

FLASH ROM

Type:

Immediate

Format:

AT [cmds] ** [cmds]

Description:

Set FLASH ROM code XMODEM upload mode

FLOW CONTROL

Type:

Configuration

Format:

AT [cmds] \Gn [cmds]

Description:

Selects modem port flow control for Normal and Direct modes

Command

Function

í \G0

Flow control disabled

\G1

Flow control enabled

FLOW CONTROL

Type:

Read-only Register

Format

AT [cmds] S39? [cmds]

Description:

Displays the current flow control

Value

Meaning

0

Flow control disabled

3

RTS/CTS flow control enabled

4

XON/XOFF flow control enabled

5

Transparent XON/XOFF flow control enabled

6

Both XON/XOFF and RTS/CTS enabled

FLOW CONTROL CHARACTER - XON

Type:

Register

Format:

AT [cmds] S32=n [cmds]

Default:

17

Range:

0-255

Unit:

ASCII

Description:

Sets the character used to represent XON

FLOW CONTROL CHARACTER - XOFF

Type:

Register

Format:

AT [cmds] S33=n [cmds]

Default:

19

Range:

0-255

Unit:

ASCII

Description:

Sets the character used to represent XOFF

INACTIVITY TIMER

Type:

Register

Format

AT [cmds] S30=n [cmds]

Default:

0

Range:

0-255

Unit:

10 seconds

Description:

Maximum duration of DTE and DCE inactivity allowed prior to initiating hang-up process.

Note: S30=0 disables the timer and allows indefinite inactivity. In Reliable mode any data transfer resets timer. In Normal mode only sent data resets timer.

LINE SIGNAL LEVEL

Type:

Immediate

Format

AT [cmds] %L [cmds]

Default:

Unidentified

Range:

9-46

Unit:

-dBm

Description:

Returns a value which indicates the received line signal level

LINE SIGNAL QUALITY

Type:

Immediate

Format

AT [cmds] %Q [cmds]

Default:

Unidentified

Range:

0-127

Unit:

Unidentified

Description:

Returns a value which indicates line signal quality (EQM)

LOCK SERIAL PORT

Type:

Configuration

Format:

AT [cmds] \Jn [cmds]

Description:

Sets operation of serial port speed

Command

Function

\J0

Serial speed locked

\J1

Serial speed follows connect speed

MAXIMUM BLOCK SIZE FOR TRANSMISSION

Type:

Configuration

Format:

AT [cmds] \An [cmds]

Description:

Sets the maximum transmittable block size

Command

Function

\A0

MNP block size is 64 characters

í \A1

MNP block size is 128 characters

\A2

MNP block size is 192 characters

\A3

MNP block size is 256 characters