SIIG, INC.
DASH 28.8I FAX/MODEM EXTERNAL
Modem Type | Data (synchronous/asynchronous)/Fax |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | External |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34 Rockwell V.FC |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |

CONNECTIONS | |||
Purpose | Location | Purpose | Location |
Line out | CN1 | Power switch | SW1 |
Line in | CN2 | Data/Voice | SW2 |
RS-232/422 | CN3 | Answer/Originate | SW3 |
AC power | CN4 | ||
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
PW | Red | On | Power is on. |
PW | Red | Off | Power is off |
TR | Red | On | DTR signal is high |
TR | Red | Off | DTR signal is low |
CS | Red | On | CTS signal is high |
CS | Red | Off | CTS signal is low |
TD | Red | Blinking | Modem is transmitting data |
TD | Red | Off | Modem is not transmitting data |
CD | Red | On | Carrier signal detected |
CD | Red | Off | Carrier signal not detected |
RD | Red | Blinking | Modem is receiving data |
RD | Red | Off | Modem is not receiving data |
AA | Red | On | Auto-answer enabled |
AA | Red | Off | Auto-answer disabled |
AA | Red | Blinking | Phone is ringing |
OH | Red | On | Modem is off-hook |
OH | Red | Off | Modem is on-hook |
Proprietary AT Command Set
AUTO-RETRAIN - FALLBACK/FALLFORWARD | |
Type: | Configuration |
Format: | AT [cmds] %En [cmds] |
Example: | AT %E1 <CR> |
Description: | Controls auto-retrain mode and fallback/fall forward. |
| Command | Function |
| » %E0 | Auto-retrain disabled. |
| %E1 | Auto-retrain enabled. |
| %E2 | Fallback/fall forward enabled. |
BIT-MAPPED REGISTERS | |
Register | Default |
S14 | 138 |
S16 | 0 |
S21 | 0 |
S23 | 54 |
S27 | 9 |
S28 | 0 |
S31 | 2 |
S36 | 7 |
S40 | 105 |
S41 | 3 |
S82 | 128 |
S91 | 10 |
S92 | 10 |
S95 | 0 |
S201 | 58 |
BREAK TYPE | |||
Type: | Configuration | ||
Format: | AT [cmds] \Kn [cmds] | ||
Example: | AT \K1 <CR> | ||
Description: | Configures action of break signal. | ||
Command | Break from DTE | Break received from remote modem | |
\K0 | Online command mode enabled, send no break to remote modem. | Buffers cleared, break sent to DTE. | |
\K1 | Break sent to remote modem and buffered cleared. | Buffers cleared, break sent to DTE. | |
\K2 | Online command mode enabled, send no break to remote modem. | Break sent immediately to DTE. | |
\K3 | Send break to remote modem immediately. | Break sent immediately to DTE. | |
\K4 | Online command mode enabled, send no break to remote modem. | Break sent with received data to the DTE. | |
\K5 | Send break with transmitted data. | Break sent with received data to the DTE. | |
CONNECT MODE | |
Type: | Configuration |
Format: | AT [cmds] \Nn [cmds] |
Example: | AT \N1 DT555-1212 <CR> |
Description: | Sets connect mode. |
| Command | Function |
| \N0 | Normal mode enabled. |
| \N1 | Serial interface enabled |
| \N2 | Reliable mode enabled. |
| \N3 | Auto-reliable mode enabled. |
| \N4 | LAPM mode enabled. |
| \N5 | MNP mode enabled. |
FLOW CONTROL CHARACTER - XON | |
Type: | Register |
Format: | AT [cmds] S32=n [cmds] |
Example: | AT S32=20 <CR> |
Default: | 17 |
Range: | 0 - 255 |
Unit: | ASCII |
Description: | Sets the character used to represent XON. |
FLOW CONTROL CHARACTER - XOFF | |
Type: | Register |
Format: | AT [cmds] S33=n [cmds] |
Example: | AT S33=20 <CR> |
Default: | 19 |
Range: | 0 - 255 |
Unit: | ASCII |
Description: | Sets the character used to represent XOFF. |
HDLC ADDRESS | |
Type: | Register |
Format: | AT [cmds] S20=n [cmds] |
Example: | AT S20=6 <CR> |
Default: | 0 |
Range: | 0 - 255 |
Unit: | N/A |
Description: | Sets the HDLC address/BSC character. |
DISPLAY LINE SIGNAL LEVEL | |
Type: | Immediate |
Format: | AT [cmds] %L [cmds] |
Example: | AT %L &W <CR> |
Description: | Displays a value of the received line signal level. |
DISPLAY LINE SIGNAL QUALITY | |
Type: | Immediate |
Format: | AT [cmds] %Q [cmds] |
Example: | AT %Q &W <CR> |
Description: | Displays line signal quality. |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] \Gn [cmds] |
Example: | AT \G1 &K3 <CR> |
Description: | Selects modem port flow control. |
| Command | Function |
| » \G0 | Flow control disabled. |
| \G1 | Flow control enabled. |
MODULATION SELECTION | |
Type: | Configuration |
Format: | AT [cmds] +MS=xx,y,zzz,aaa [cmds] |
Example: | AT +MS11,1,300,28800 &W <CR> |
Description: | Sets options for active protocol. The transfer rates specified by z and a must be valid for the protocol selected. |
| Command | Function |
| x=0 | V.21 |
| x=1 | V.22 |
| x=2 | V.22bis |
| x=3 | V.23 |
| x=9 | V.32 |
| x=10 | V.32bis |
| » x=11 | V.34 |
| x=64 | Bell 103A |
| x=69 | Bell 212A |
| x=74 | V.FC |
y =0 | Automode disabled. |
y =1 | Auto-detect highest speed enabled. |
z, a =300 | Set minimum or maximum transfer rate at 300bps, respectively. |
z, a =1200 | Set minimum or maximum transfer rate at 1200bps, respectively. |
z, a =2400 | Set minimum or maximum transfer rate at 2400bps, respectively. |
z, a =4800 | Set minimum or maximum transfer rate at 4800bps, respectively. |
z, a =7200 | Set minimum or maximum transfer rate at 7200bps, respectively. |
z, a =9600 | Set minimum or maximum transfer rate at 9600bps, respectively. |
z, a =12000 | Set minimum or maximum transfer rate at 12000bps, respectively. |
z, a =14400 | Set minimum or maximum transfer rate at 14400bps, respectively. |
z, a =16800 | Set minimum or maximum transfer rate at 16800bps, respectively. |
z, a =19200 | Set minimum or maximum transfer rate at 19200bps, respectively. |
z, a =21600 | Set minimum or maximum transfer rate at 21600bps, respectively. |
z, a =24000 | Set minimum or maximum transfer rate at 24000bps, respectively. |
z, a =26400 | Set minimum or maximum transfer rate at 26400bps, respectively. |
z, a =28800 | Set minimum or maximum transfer rate at 28800bps, respectively. |
MODULATION SELECTION DISPLAY | |
Type: | Immediate |
Format: | AT [cmds] +MS? |
Example: | AT &V +MS? <CR> |
Description: | Displays modulation, automode, minimum rate and maximum rate settings |
V.42 HANDSHAKE OPTIONS | |
Type: | Register |
Format: | AT [cmds] S48=n [cmds] |
Example: | AT S48=7 <CR> |
Default: | 7 |
Range: | 0, 7, or 128 |
Description: | Controls the V.42 handshake sequence. |
Command | Function |
| S48=0 | V.42 negotiation disabled. |
| » S48=7 | V.42 negotiation enabled. |
| S48=128 | V.42 disabled; fallback according to S36. |