SYNERGY SOLUTIONS
SS-558
Card Type | Serial card |
Chipset Controller | 16C554 UART (2) |
I/O Options | Serial port (8 serial port connectors on external cable) |
Maximum DRAM | N/A |

CONNECTIONS | |
Purpose | Location |
78-pin serial port interface connector | CN1 |
BANK A SERIAL PORT INTERRUPT SELECTION (PORTS 1 - 4) | |||||||
| IRQ | S2/1 | S2/2 | S2/3 | S2/4 | S2/5 | S2/6 | |
| » | 5 | Off | Off | Off | On | Off | Off |
| 2 | On | Off | Off | Off | Off | Off | |
| 3 | Off | On | Off | Off | Off | Off | |
| 4 | Off | Off | On | Off | Off | Off | |
| 6 | Off | Off | Off | Off | On | Off | |
| 7 | Off | Off | Off | Off | Off | On | |
BANK B SERIAL PORT INTERRUPT SELECTION (PORTS 5 - 8) | |||||||
| IRQ | S4/1 | S4/2 | S4/3 | S4/4 | S4/5 | S4/6 | |
| » | 5 | Off | Off | Off | On | Off | Off |
| 2 | On | Off | Off | Off | Off | Off | |
| 3 | Off | On | Off | Off | Off | Off | |
| 4 | Off | Off | On | Off | Off | Off | |
| 6 | Off | Off | Off | Off | On | Off | |
| 7 | Off | Off | Off | Off | Off | On | |
SERIAL PORT CONFIGURATION | |
IRQB | S4/7 |
Single interrupt selected on S2 Bank A for all eight ports | On |
All ports not using same interrupt | Off |
Note: This switch work in conjunction with the setting of interrupts for Bank A (S2) & Bank B (S4). | |
BASE I/O ADDRESS SELECTION (BANK A SERIAL PORT 1 - 4) | ||||||||
| Address | S1/1 | S1/2 | S1/3 | S1/4 | S1/5 | S1/6 | S1/7 | |
| » | 100h | On | On | On | Off | On | On | On |
| 120h | Off | On | On | Off | On | On | On | |
| 140h | On | Off | On | Off | On | On | On | |
| 160h | Off | Off | On | Off | On | On | On | |
| 180h | On | On | Off | Off | On | On | On | |
| 0F60h | Off | Off | On | Off | Off | Off | Off | |
| 0F80h | On | On | Off | Off | Off | Off | Off | |
| 0FA0h | Off | On | Off | Off | Off | Off | Off | |
| 0FC0h | On | Off | Off | Off | Off | Off | Off | |
| 0FE0h | Off | Off | Off | Off | Off | Off | Off | |
Note: A total of 128 base address settings are available. The switches are a binary representation of the decimal memory addresses. S1/7 is the Most Significant Bit and switch S1/1 is the Least Significant Bit. The switches have the following decimal values: S1/7=2048, S1/6=1024, S1/5=512, S1/4=256, S1/3=128, S1/2=64, S1/1=32. Turn off the switches and add the values of the switches that are off to obtain the correct memory address. (Off=1, On=0) | ||||||||
BASE I/O ADDRESS SELECTION (BANK B SERIAL PORT 5 - 8) | ||||||||
| Address | S3/1 | S3/2 | S3/3 | S3/4 | S3/5 | S3/6 | S3/7 | |
| » | 120h | Off | On | On | Off | On | On | On |
| 100h | On | On | On | Off | On | On | On | |
| 140h | On | Off | On | Off | On | On | On | |
| 160h | Off | Off | On | Off | On | On | On | |
| 180h | On | On | Off | Off | On | On | On | |
| 0F60h | Off | Off | On | Off | Off | Off | Off | |
| 0F80h | On | On | Off | Off | Off | Off | Off | |
| 0FA0h | Off | On | Off | Off | Off | Off | Off | |
| 0FC0h | On | Off | Off | Off | Off | Off | Off | |
| 0FE0h | Off | Off | Off | Off | Off | Off | Off | |
Note: A total of 128 base address settings are available. The switches are a binary representation of the decimal memory addresses. S3/7 is the Most Significant Bit and switch S3/1 is the Least Significant Bit. The switches have the following decimal values: S3/7=2048, S3/6=1024, S3/5=512, S3/4=256, S3/3=128, S3/2=64, S3/1=32. Turn off the switches and add the values of the switches that are off to obtain the correct memory address. (Off=1, On=0) | ||||||||
FACTORY CONFIGURED - DO NOT ALTER | |
Switch | Position |
S2/7 | Off |