INDUSTRIAL COMPUTER SOURCE
16REL-L
Card Type | Parallel card |
I/O Options | serial port |
Data Bus | 8-bit ISA |
CONNECTIONS | |
Function | Label |
DB-37 connector | CN1 |
USER CONFIGURABLE SETTINGS: PORT ENABLE/DISABLE | ||
Setting | Label | Position |
16REL-L port enabled | SW1/8 | On |
16REL-L port disabled | SW1/8 | Off |
BASE I/O ADDRESS SELECTION | |||||||||
Address Port A | Address Port B | SW1/1 | SW1/2 | SW1/3 | SW1/4 | SW1/5 | SW1/6 | SW1/7 | |
» | 300 | 303 | Off | On | On | On | On | On | On |
| 304 | 307 | Off | On | On | On | On | On | Off |
| 308 | 30F | Off | On | On | On | On | Off | On |
| 310 | 313 | Off | On | On | On | Off | On | On |
| 314 | 317 | Off | On | On | On | Off | On | Off |
| 320 | 323 | Off | On | On | On | Off | On | On |
| 3A0 | 3A3 | Off | Off | On | Off | On | On | On |
Note: A total of 255 base address settings are available. The switches are a binary representation of the decimal memory addresses. SW1/1 is the Most Significant Bit and switch SW1/8 is the Least Significant Bit. The switches have the following decimal values: SW1/1=256, SW1/2=128, SW1/3=64, SW1/4=32, SW1/5=16, SW1/6=8, SW1/7=4. Turn off the switches and add the values of the switches, including an additional value of 512 as a fixed setting, to obtain the correct memory address. (Off=1, On=0) |
MISCELLANEOUS TECHNICAL NOTES | |