7 5 4 0 A MAXTOR
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders | | |
Capacity form/unform 540/ MB Heads 4| | |
Seek time / track 14.0/ 3.0 ms Sector/track | | |
Controller IDE / ATA2 FAST/ENHA Precompensation
Cache/Buffer 32 KB ON-BOARD Landing Zone
Data transfer rate 3.000 MB/S int Bytes/Sector 512
11.100 MB/S ext PIO3
Recording method operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 50 | -40 71
Power: sleep 0.6 W Humidity % 5 95 | 5 95
standby 0.7 W Altitude km -0.061 3.048|
idle 3.9 W Shock g 15 | 70
seek 4.2 W Rotation RPM 3551
read/write 4.2 W Acoustic dBA
spin-up 15.1 W ECC Bit
MTBF h 300000
Warranty Month
Lift/Lock/Park YES Certificates
Layout
MAXTOR 7540A JUMPER SETTING
+---------------------------------------------------------+
| J20-+-+-+-+-+-J25 |
| +-+-+-+-+-+-+ |
| |
| XX
| XX
| XX
| XX J1
| X*
| XX
| XX
| XX
| XX
| XX1-2
| | 1
| XX Power
| XX J2
+---------------------------------------------------------+
Jumpers
MAXTOR 7540A JUMPER SETTING
Jumper setting
==============
Note: Jumpers J21 and J25 are factory reserved. A spare shunt is
shipped between J23 and J24.
J20 Master/Slave
-----------------
J20 CLOSED Only drive in single drive system (Default)
J20 CLOSED Master in dual drive system
J20 OPEN Slave in dual drive system
J22 Default Parameters (7540A only)
------------------------------------
J22 OPEN 1046 x 16 x 63 (default)
CLOSED 1024 x 16 x 63
J23 Write Cache
----------------
J23 OPEN Enabled (default)
J23 CLOSED Disabled
J24 Cable Select
-----------------
J24 OPEN Disabled (default)
J24 CLOSED Enabled
Share and Enjoy
Bookmark this story so others can enjoy it:
Tags
hard drive, hdd, hard disc, 7540A, 540MB, 3.5