Articles / TULARC / PC info / Hard Drives / FUJITSU Hard Drives / | ![]() |
|
![]() |
||||
![]() |
![]() |
|||
![]() |
![]() |
|||
![]() |
||||
|
|
||||
![]() |
![]() |
|||
![]() |
Hard Drive: FUJITSU: M1606TAU PICOBIRD 7 1089MB 3.5"/SL ATA2 FAST |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
||
![]() |
||||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
|
|
||
![]() |
||
![]() |
![]() |
![]() |
![]() |
||
![]() |
||
M 1 6 0 6 T A U P I C O B I R D 7 FUJITSU
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 3456| 2111| |
Capacity form/unform 1089/ MB Heads 6| 16| |
Seek time / track 10.0/ 3.0 ms Sector/track | 63| |
Controller IDE / ATA2 FAST/ENHA Precompensation
Cache/Buffer 256 KB Landing Zone
Data transfer rate 5.500 MB/S int Bytes/Sector 512
16.700 MB/S ext PIO4
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 60
Power: sleep W Humidity % 8 80 | 5 95
standby W Altitude km -0.300 3.000| -0.300 12.000
idle W Shock g 5 | 50
seek W Rotation RPM 5400
read/write W Acoustic dBA 38
spin-up W ECC Bit
MTBF h 300000
Warranty Month 24
Lift/Lock/Park YES Certificates
FUJITSU M1603TA/1606TA JUMPER SETTING A1CA 01310-0012
+---------------------------------------------------------+ | | | |XX | |XX | |XX | CNH1 |XX | 9++++++ |XX | ++++++2 |XX | |XX | |XX | |XX | |XX | |XX | |XX | |XX | |XX +5V | |XX RETURN | |XX +12V +---------------------------------------------------------+
FUJITSU M1603TA/M1606TA JUMPER SETTING A1CA 01310-0011
Jumper Setting
==============
CNH1 Jumper Setting
-------------------
+------+--------------------+-------+--------+-------------------+ | Pin | Function | OPEN | CLOSED | Remarks | +------+--------------------+-------+--------+-------------------+ | 1-2 | Drive type select | Slave | Master*| - | +------+--------------------+-------+--------+-------------------+ | 3-4 | RESERVED | | | NOT USED | +------+--------------------+-------+--------+-------------------+ | 5-6 | Auto Idle control | Enable|Disable*| - | +------+--------------------+-------+--------+-------------------+ | 7-8 | CSEL connected to | No* | Yes | Supported needed | | | interface | | | from host (NOTE1)| +------+--------------------+-------+--------+-------------------+ | 9-10 | RESERVED | | | NOT USED | +------+--------------------+-------+--------+-------------------+
NOTE1
CSEL: Cable select mode gives an alternative method by which the
drive may be set to MASTER or SLAVE. A special cable is
needed to implement this feature and should only be used if
supported by BOTH drives. CSEL mode should be used in
conjunction with SLAVE and without ACMODE.
* = DEFAULT
FUJITSU M1603TA/M1606TA JUMPER SETTING A1CA 01310-0011
Notes on installation
=====================
Drive mounting
--------------
horizontally vertically
+-----------------+ +--+ +--+ +------------------+
| | | +-----+ +-----+ | | | x
| | | | | | | | x+----------------+x
+-+-----------------+-+ | | | | | | ||x x||
+---------------------+ | | | | | | || x x ||
| | | | | | || x x ||
x x | | | | | | || x x ||
+------x------x-------+ | +-----+ +-----+ | || xx ||
+-+------x--x-------+-+ +--+ +--+ || x x ||
| xx | || x x ||
| x x | || x x ||
+---x--------x----+ |x x|
x x x++----------------++x
UNACCEPTABLE! UNACCEPTABLE!
Orientation
-----------
The drive may be installed in one of three orientations; PCA down
or on either edge. Inclination from vertical or horizontal should
not exceed 5*.
Mounting screw fixing
---------------------
When the mounting screw holes on the side of the drive are used, then
use only the two pairs of outer holes. Do not use the centre hole
in conjunction with only one of the outer holes. The screw must not
penetrate the drive by more than 4.5 millimetres.
Grounding
---------
Sufficient grounding will be provided for correct operation when
the drive is screwed into an electrically grounded frame.
Cooling
-------
Allow space above and below the drive to provide for adequate air
flow. Fan cooling is recommended. The disk enclosure temperature,
measured at top centre, should never exceed 60*C.